Bravox RV18-S4 2.2KW
18″ subwoofer · 4 Ω · 1,100 W RMS
The Bravox RV18-S4 2.2KW is a 18″ subwoofer. With Qts 0.49 and EBP 51 it works both sealed and ported: sealed is tighter and smaller, ported is deeper and louder. Modest excursion (Xmax 0.30″) — for clean sound at moderate levels, not for SPL competitions.
| Source | From the manufacturer · website web.archive.org |
|---|---|
| Checked against source | October 2026 |
| Thiele/Small parameters | from datasheet: 8 · calculated: 1 · estimate: 1 |
| Mounting dimensions | 0 of 4 — missing: cutout, mounting depth, frame outer diameter, magnet diameter; the designer will use an estimate |
Recommended box
We calculated it from the manufacturer’s data; the manufacturer has not reviewed this enclosure. For a sedan, one sub, 940 W. It’s the same math as the designer’s step-by-step mode, where you can fit the box to your space, vehicle and amp and get plans, a cut sheet and DXF.
Sealed
smaller, tighter| Bass character (Qtc) | Tight and punchy · 0.80 |
|---|---|
| Fc | 49 Hz |
| F3 (−3 dB, no cabin gain) | 47 Hz |
| Example box (outside) | 31 1/2″ × 20 1/2″ × 11 5/8″ |
| Operating limits | 660 W, subsonic 29 Hz |
At the rated 1,100 W, excursion in this box is more than 15% over Xmax 0.30″, so the checked operating mode is up to 660 W, subsonic filter 29 Hz. The example opens in the designer with it; for full power, size the box and filter there.
In this mode excursion of 0.34″ is slightly over Xmax 0.30″: expect more distortion when it's loud. For clean bass, the designer suggests a subsonic filter or power setting.
Open sealed box in the calculatorPorted
deeper, louderManufacturer's advice: 4.06 ft³
Source: manufacturer's product page · archived copy of bravox.com.br (Wayback Machine) · recorded November 2, 2026
| Tuning (Fb) | 33 Hz |
|---|---|
| Port | slot 2 3/8 × 19 1/16″, 21 11/16″ long |
| Port velocity at 940 W | 54 ft/s |
| F3 (−3 dB, no cabin gain) | 34 Hz |
| Example box (outside) | 31 1/2″ × 20 1/2″ × 16 9/16″ |
| Operating limits | 940 W, subsonic 29 Hz |
At the rated 1,100 W, excursion in this box is more than 15% over Xmax 0.30″, so the checked operating mode is up to 940 W, subsonic filter 29 Hz. The example opens in the designer with it; for full power, size the box and filter there.
In this mode excursion of 0.34″ is slightly over Xmax 0.30″: expect more distortion when it's loud. For clean bass, the designer suggests a subsonic filter or power setting.
Open ported box in the calculatorDeeper: 7.73 ft³ (219 L) tuned to 30 Hz — −3 dB at 29 Hz instead of 34 Hz, 31 1/2″ × 20 1/2″ × 28 3/16″ outside. Open in the calculator
Matching amplifiers
All amplifiers ›This sub handles 1,100 W RMS. A matching amp gives 75–110 % of that at the wiring's final load. CEA/CTA-2006 rated amps come first; “MAX only” models are not shown.
1 sub → 4 Ω
Needs 830–1,210 W at 4 Ω
| Model | Brand | at 4 Ω | of RMS | Spec sheet |
|---|---|---|---|---|
| BP4000.1 | Massive Audio | 1,000 W | 91 % | CTA-2006 |
| P1000X2 | Rockford Fosgate | 1,000 W | 91 % | CTA-2006 |
| T1500-1bdCP | Rockford Fosgate | 1,000 W | 91 % | CTA-2006 |
2 subs → 2 Ω
Needs 1,650–2,420 W at 2 Ω (2 × 1,100 W)
Projects with this subwoofer
Boxes that users designed and published: plans, cut sheet and response graph.
Manufacturer spec sheet
From the manufacturer · website
Values as in the source, before conversion for the calculation. Source: web.archive.org/web/20140727035654/http://www.bravox.com.…
- Fs · resonance
- 30 Hz
- Qts · total Q
- 0.48
- Qes · electrical Q
- 0.59
- Qms · mechanical Q
- 2.75
- Vas · equivalent volume
- 5.30 ft³
- Sd · cone area
- 199.7 in²
- Xmax · one-way excursion
- 0.30″
- BL · motor strength
- 20.4 T·m
- Pe · RMS power
- 1,100 W
Calculated and estimated
Our calculation
These values are missing from the spec sheet or don’t add up. This is how the calculator takes them.
- Re
- ≈ 3.4 Ω
- estimate · not in datasheet; 0.85 × nominal coil impedance
Thiele/Small parameters
| Size | 18″ |
|---|---|
| Voice coils | 4 Ω |
| RMS power | 1,100 W |
| Fs | 30 Hz |
| Qts | 0.49 |
| Qes | 0.59 |
| Qms | 2.75 |
| Vas | 5.30 ft³ |
| Re | ≈ 3.4 Ω |
|---|---|
| Sd | 199.7 in² |
| Xmax | 0.30″ |
| Vd | 59 in³ calc. |
| Mms | 441 g calc. |
| BL | 21.9 T·m calc. |
| EBP | 51 — sealed or ported calc. |
| Sensitivity, 1 W / 1 m | 90.4 dB calc. |
Mounting dimensions
| Cutout diameter | ≈ 16 9/16″ |
|---|---|
| Mounting depth | ≈ 8 1/4″ |
No mark — from the manufacturer's spec sheet (sources below); “≈” means the value isn’t in the spec sheet and a typical value for the size is used; “calc.” means it’s calculated from the published parameters. Check the manufacturer’s spec sheet before you build.
Data sources
Other Bravox 18″ models
- Bravox RV18-S4 5.1KW 18″ · 4 Ω
Similar 18″ subwoofers from other brands
Close in Fs, Qts and Vas — a box of similar volume will suit them.
- Sundown Audio Xv2-18 D4 2.90 ft³ sealed · 3.88 ft³ ported
- Fi Audio NEO 4.7 18 D1 2.79 ft³ sealed · 3.57 ft³ ported
- Fi Audio NEO 4.7 18 D2 2.79 ft³ sealed · 3.57 ft³ ported
- Fi Audio Q18 D1 3.74 ft³ sealed · 4.66 ft³ ported
- Fi Audio Q18 NEO D1 3.74 ft³ sealed · 4.66 ft³ ported
- Fi Audio Q18 NEO D2 3.74 ft³ sealed · 4.66 ft³ ported
- Fi Audio Xv5 18 D1 2.54 ft³ sealed · 4.31 ft³ ported
All 18″ subwoofers in our database →
FAQ
What box does the Bravox RV18-S4 2.2KW need?
Recommended net volume: 3.11 ft³ sealed, 4.06 ft³ ported tuned to 33 Hz — for one sub in a sedan at 940 W. Fit the box to your space and amp in the free calculator, with plans and a cut sheet.
What are the Bravox RV18-S4 2.2KW Thiele/Small specs?
Fs 30 Hz, Qts 0.49, Vas 5.30 ft³, Xmax 0.30″, Sd 199.7 in².
How much power does the Bravox RV18-S4 2.2KW handle and how do I wire it?
RMS power rating: 1,100 W. Wiring for several subs and amp power — in the wiring calculator. What size amp Bravox RV18-S4 2.2KW needs — the amp calculator with this model.
Is the Bravox RV18-S4 2.2KW better sealed or ported?
EBP 51: both work — sealed 3.11 ft³ is tighter and smaller, ported 4.06 ft³ tuned to 33 Hz is deeper and louder.
What port does the Bravox RV18-S4 2.2KW need?
For the 4.06 ft³ ported box tuned to 33 Hz: slot 2 3/8 × 19 1/16″, 21 11/16″ long, area 45 in²; or a round port Ø7 9/16″, ≈ 21 11/16″ long. Port air speed at 940 W: 54 ft/s. Different port size? Get the length in the port length calculator.
What box do two Bravox RV18-S4 2.2KW subs need?
Two subs need twice the volume: 6.22 ft³ sealed, or 8.12 ft³ ported at the same 33 Hz tuning with twice the port area. One shared chamber or one per sub — whatever fits your vehicle.